Multiparameter (Pro Plus) (DO, pH, Cond, Temp, ORP, Ammonia, Ammonium, Nitrate, Chloride, Built-in barometer)

Available on backorder

Operating Temp: -10 to 60°C
Data Manag.: 5000 data set
Model.:Professional Plus
Brand: YSI
Country: USA

The Quatro cable attached to the Pro Plus allows you to utilize 4-ports to measure temperature/conductivity, DO, and any two ISEs among pH, ORP, ammonium, chloride, or nitrate creating an extremely powerful handheld multiparameter instrument.
Toughest
The Pro Plus instrument meets the demands of true field work. The instrument is rated to IP-67 standards even without the battery cover on. Other tough features include a 3-year warranty, Mil-spec connectors, rubber overmolded case, and a 2-year cable warranty. In-house testing procedures also include 1-meter drop tests from all angles to ensure expected field-durability.
Tough, Field Durability Features Include:
    Easy-to-install cable weights; can be daisy-chained for additional weight*
    Rubber, over-molded IP-67 waterproof case (even without the battery cover)*
    3-year instrument warranty
    2-year cable warranty*
    Rugged cables, sensors, and military-spec connectors*
    Drop-tested 1 meter at all angles*
    Scratch-resistant lens; viewable with polarized glasses
    Instrument floats
    Weighted, user-replaceable multi-sensor design
Smartest
The instrument provides numerous benefits from the following features; 5,000 data-set memory, password protection, backlit display and keypad, graphic display with detailed Help functionality, re-cal prompts, user defined fields, detailed GLP, auto stable, Hold All Readings function, Data Manager software for the desktop, USB connection, auto-buffer recognition, and flexible folders and site lists for logging data.
Smart Features Include:
    5,000 data set memory
    Detailed on-screen Help function*
    Free, Data Manager desktop software and ProComm II saddle*
    Interval or single-event logging
    100 folder & site list data structure*
    Password protection
    Detailed GLP data
    USB connection also powers the instrument
    6-point cal with auto-buffer recognition*
    User-adjustable auto-stable with prompts*
    User-upgradeable software via waterproof USB port
    Recalibration prompts

Specification:

AutostableUser-defined auto-stable function holds stable readings on display when criteria is met
CertificationsRoHS, CE, WEEE, C-Tick, VCCI, FCC, IP-67 (waterproof), 1-meter drop test, Assembled in USA
Connectivity / CommunicationsUSB 2.0 for data transfer and user-upgradeable instrument firmware. Communications saddle, USB cable and Data Manager software included
ConnectorMetal MS (military spec) waterproof with bayonet lock
Data Management5000 data set memory in Pro Plus with 100 user-defined sites and site names. Data Manager desktop software included
Desktop Software CompatibleData Manager desktop software included. Minimum PC requirements – Windows 2000 with SP4 (minimum) or XP with SP2 (minimum), Vista 7 or Windows 8 | 300 MHz or higher Pentium-compatible CPU | 128 MB of RAM or higher | 80 MB or more of free hard-disk space
Digital / Digital SensorsNo, the Pro Plus is an analog instrument
GLP ComplianceYes, detailed GLP information is stored and is available to view, download or print
Graphic DisplayGraphic display can be seen in any lighting condition and with polarized glasses | Backlit display AND keypad | Includes detailed on-board Help
LanguagesEnglish, Chinese (Simplified and Traditional), Italian, Japanese, French, German, Portuguese, Spanish, Norwegian
Logging CapabilitiesSingle or Continuous
Memory100 GLP files, 5,000 data sets (data, date, time, user-defined info)
MultiparameterYes
Operating Temperature-10 to 60°C
Parameters MeasuredTemperature, Dissolved Oxygen, pH, ORP/Redox, Conductivity, TDS, Ammonia, Ammonium, Nitrate, Chloride,Built-in barometer
PowerProComm II saddle provides USB power or optional wall power, cigarette lighter, and universal cell phone charger options, 2 alkaline C-cells provide 80 continuous hours at ambient temperature without backlight
SamplingYes
Storage Temperature-20 to 70°C
Unit of MeasureConductivity-mS/cm, Barameter-mmHg, pH-units, Chloride-mg/L, Salinity-ppt, ORP-mV, Temperature- °C, mg/L, air saturation, Nitrate-mg/L-N, Dissolved Oxygen-%, Total Dissolved Solids(TDS)-g/L, Ammonium-mg/L-N, °F
User CalibratableYes
User ReplaceableYes, cables and most sensors are user-replaceable
Warranty3-year instrument; 2-year field cables
WaterproofIP-67 (even with the battery cover off and cable disconnected), floats
BarometerBuilt-in barometer
Buffer RecognitionAuto buffer recognition for US and NIST buffers
Cables: FieldStandard lengths of 1, 4, 10, 20, or 30 meters – up to 100 meters on DO only cables;  4- through 30-meter cables include a cable management kit
Cables: LabBOD sensor includes 2-meter cable; 1 or 4 meters on lab pH, ORP and pH/ORP cables
Dimensions8.3 cm width x 21.6 cm length x 5.6 cm depth (3.25 in x 8.5 in x 2.21 in)
DO Membrane Response Times (T95; 100%-0) and Required Flow Rate1.25 mil PE = 8 seconds and 6 in/sec flow
2.0 mil PE = 17 seconds and 3 in/sec flow
1 mil Teflon® = 18 seconds and 12 in/sec flow
DO SensorsPolarographic or galvanic field sensors; self-stirring polarographic BOD sensor for the lab
Flow CellSingle, dual and multiparameter Quatro cable all flow cell compatible
User IDOptional user ID for data security
Weight475 grams (1.05 lbs)

 

Parameter UnitSonsor TypeRangeAccuracyResolationCalibaration
Ammonium*Ion Selective Electrode0 to 200 mg/L-N, 0 to 30°C±10% of reading or 2 mg/L-N, whichever is greater0.01 mg/L1, 2, or 3 point
(mg/L-N mV)(user selectable)
ammonia with pH sensor
BarometerPiezoresistive375 to 825 mmHg±1.5 mmHg from 0 to 50°C0.1 mmHg1 point
(mmHg, inHg, mbar, psi, kPa, ATM)
Chloride*Ion Selective Electrode0 to 1000 mg/L, 0 to 40°C​±15% of reading or 5 mg/L, whichever is greater0.01 mg/L1, 2, or 3 point
(mg/L-Cl-, mV)(user selectable)
Conductivity**Four Electrode Cell0 to 200 mS/cm (auto-range)1 m, 4 m cables:Range dependent1 point
(µS, mS)±0.5% of reading or 0.001 mS/cm, whichever is greater
20 m cable:0 to 0.500 mS/cm: 0.001
 ±1% of reading or 0.001 mS/cm, whichever is greater0.501 to 50.00 mS/cm: 0.01
50.01 to 200 mS/cm: 0.1
Dissolved OxygenPolarographic or Galvanic0 to 500%0 to 200% :0.1% or 1% air saturation (user selectable)1 or 2-points with zero
(% saturation)± 2% of reading or 2% air saturation, whichever is greater
temp comp range -5 to 50°C200% – 500% :
± 6% of reading
Dissolved OxygenPolarographic or Galvanic0 to 50 mg/L0 to 20 mg/L :0.1 or 0.01 mg/L (user selectable); 0.1% air saturation1 or 2-points with zero
(mg/L, ppm)± 2% of reading or 0.2 mg/L, whichever is greater
temp comp range -5 to 50°C20 – 50 mg/L :
± 6% of reading
Nitrate*Ion Selective Electrode0 to 200 mg/L-N, 0 to 30°C±10% of reading or 2 mg/L-N, whichever is greater0.01 mg/L1, 2, or 3 point
(mg/L-N mV)(user selectable)
ORPPlatinum Button-1999 to +1999 mV±20 mV in redox standards0.1 mV1 point
(mV)
pHGlass Combination Electrode0 to 14 units±0.2 units0.01 units1, 2, 3, 4, 5, or 6 point (user selectable); US, NIST or Custom Buffers
(mV, pH units)
SalinityCalculated from Conductivity and Temperature0 to 70 ppt±1.0% of reading or ±0.1 ppt, whichever is greater0.01 ppt1 point
(ppt, PSU)
TemperatureThermistor-5 to 70°C (23 to 158°F)0.1°CNone
Field-rugged cables±0.2°C;
(°C, °F, K)±0.3°C cables over 45-meters
Temperature***Thermistor0 to 40°C (32 to 104°F)±0.35°C0.1°CNone
Lab-grade cables​
(°C, °F, K)
Total Dissolved Solids (TDS)Calculated from Conductivity and Temperature0 to 100 g/L; TDS constant range 0.30 to 1.00 (0.65 default)0.001, 0.01, 0.1g/L
(mg/L, kg/L, g/L)

 

Click here for details >>>>>

Reviews

There are no reviews yet.

Be the first to review “Multiparameter (Pro Plus) (DO, pH, Cond, Temp, ORP, Ammonia, Ammonium, Nitrate, Chloride, Built-in barometer)”

Your email address will not be published. Required fields are marked *

Related Items

৳ 90.00

Add to cart

৳ 80.00

Add to cart

৳ 28,000.00

Add to cart

৳ 150.00

Add to cart
Scroll to Top