Testo 310 – Flue Gas Analyzer (Standard Kit)
Overview
The Testo 310 Flue Gas Analyser combines simple functions with a high level of measurement accuracy, and is perfect for all basic measurements on heating systems. Long battery lifetimes of up to 10 hours guarantee high availability. It’s easy handling and compact design make the testo 310 a robust tool for daily work – even when things get rough.
With its capability to perform both basic or more complex combustion analysis, perform maintenance or safety checks, or confirm boiler efficiency, the fully featured testo 310 residential combustion analyser is ready to provide accurate analysis. The stainless steel probe and cone-stop is perfect for residential, and boiler efficiency applications. Simple top-of-display icons show you the current measurement functions. After only 30 seconds, the 310 is ready to test. With five different fuels to select from (Natural Gas, Propane, Fuel Oil 2, Biomass 5%, Wood 20%), it provides the flexibility you need for all your residential combustion analysis applications.
Measures:
- O2, CO (with built-in NOx filter), CO2
- Undiluted CO (CO air free)
- Ambient CO
- Draft & Pressure
- Temperature (flue & ambient)
- Combustion/flue gas efficiency & excess air
Delivery Scope
testo 310 – Flue Gas Analyser, Hard case, rechargeable battery, usb mains cable, silicon hose for pressure, 5 x filters, calibration protocol, 180mm probe with cone, spare pressure plugs.
Technical data
General technical data
Weight | (with probe) Approx. 700 g |
---|---|
Dimensions | 201 x 83 x 44 mm |
Operating temperature | -5 to +45 °C |
Display type | LCD (Liquid Crystal Display) |
Display function | Backlit 2-line display |
Power supply | Battery: 1500 mAh, mains unit 5V/1A |
Storage temperature | -20 to +50 °C |
Temperature – TC Type K (NiCr-Ni)
Measuring range | -20 to +100 °C |
---|---|
Accuracy | ±1 °C |
Resolution | 0.1 °C |
Reaction time | < 50 s |
Temperature (ambient temperature) |
Temperature – TC Type J (Fe-CuNi)
Measuring range | 0 to +400 °C |
---|---|
Accuracy | ±1 °C (0 to +100 °C) ±1.5 % of mv (> 100 °C) |
Resolution | 0.1 °C |
Reaction time | < 50 s |
Temperature (flue gas) |
Flue gas O₂
Measuring range | 0 to 21 Vol.% |
---|---|
Accuracy | ±0.2 Vol.% |
Resolution | 0.1 Vol.% |
Reaction time t₉₀ | 30 s |
Differential Pressure flue gas Draught – Piezoresistive
Measuring range | -20 to +20 hPa |
---|---|
Accuracy | ±1.5 % of mv (Remaining Range) ±0.03 hPa (-3.00 to +3.00 hPa) |
Resolution | 0.01 hPa |
Flue gas degree of effectivity, Eta (calculated)
Measuring range | 0 to 120 % |
---|---|
Resolution | 0.1 % |
Flue gas loss (calculated)
Measuring range | 0 to 99.9 % |
---|---|
Resolution | 0.1 % |
Flue gas CO₂ calculation (calculated from O₂)
Measuring range | 0 to CO₂ max (Display range) |
---|---|
Accuracy | ±0.2 Vol.% |
Resolution | 0.1 Vol.% |
Reaction time t₉₀ | < 40 s |
Pressure measurement
Measuring range | -40 to +40 hPa |
---|---|
Accuracy | ±0.5 hPa |
Resolution | 0.1 hPa |
Flue gas CO (without H₂-compensation)
Measuring range | 0 to 4000 ppm |
---|---|
Accuracy | ±10 % of mv (2001 to 4000 ppm) ±20 ppm (0 to 400 ppm) ±5 % of mv (401 to 2000 ppm) |
Resolution | 1 ppm |
Reaction time t₉₀ | 60 s |
Ambient CO
Measuring range | 0 to 4000 ppm |
---|---|
Accuracy | ±10 % of mv (2001 to 4000 ppm) ±20 ppm (0 to 400 ppm) ±5 % of mv (401 to 2000 ppm) |
Resolution | 1 ppm |
Reaction time | 60 s |